Planning condition
Floor levels
About this entity
| Fact links | ||
|---|---|---|
| CURIE | planning-condition:U0119446 | no fact link |
| Prefix | planning-condition | Facts about Prefix |
| Reference | U0119446 | Facts about Reference |
| Name | Floor levels | Facts about Name |
| Quality | Authoritative: We have some data from the authoritative source | no fact link |
| Dataset | Planning condition | no fact link |
| Organisation | Doncaster Metropolitan Borough Council | no fact link |
| Start date | Facts about Start date | |
| End date | Facts about End date | |
| Entry date | 2025-06-24 | Facts about Entry date |
| Typology | policy | no fact link |
| Notes | Unique Condition | Facts about Notes |
| Reason | To reduce the risk of flooding to the proposed development and future occupants. | Facts about Reason |
| Description | The development shall be carried out in accordance with the submitted flood risk assessment (ref 2880 / Aug 2021 / REV A / J Roberts Design Ltd) and the following mitigation measures it details: i) Finished floor levels shall be set no lower than 6.435 metres above Ordnance Datum (AOD) ii) As per the submitted floor plans, there shall be no ground floor sleeping accommodation within Flood Zone 3 (House Type E Alt) iii) The apartment block (Type C) that proposes ground floor sleeping will be fully located within flood zone 2, as shown in the submitted site plan. These mitigation measures shall be fully implemented prior to occupation and subsequently in accordance with the scheme's timing/phasing arrangements. The measures detailed above shall be retained and maintained thereafter throughout the lifetime of the development. | Facts about Description |
Contents
{
"entry-date": "2025-06-24",
"start-date": "",
"end-date": "",
"entity": 73008819,
"name": "Floor levels",
"dataset": "planning-condition",
"typology": "policy",
"reference": "U0119446",
"prefix": "planning-condition",
"organisation-entity": 109,
"geometry": "",
"point": "",
"quality": "authoritative",
"notes": "Unique Condition",
"reason": "To reduce the risk of flooding to the proposed development and future occupants.",
"description": "The development shall be carried out in accordance with the submitted flood risk assessment (ref 2880 / Aug 2021 / REV A / J Roberts Design Ltd) and the following mitigation measures it details: i) Finished floor levels shall be set no lower than 6.435 metres above Ordnance Datum (AOD) ii) As per the submitted floor plans, there shall be no ground floor sleeping accommodation within Flood Zone 3 (House Type E Alt) iii) The apartment block (Type C) that proposes ground floor sleeping will be fully located within flood zone 2, as shown in the submitted site plan. These mitigation measures shall be fully implemented prior to occupation and subsequently in accordance with the scheme's timing/phasing arrangements. The measures detailed above shall be retained and maintained thereafter throughout the lifetime of the development."
}
© Crown copyright and database right 2026
Licensed under the Open Government Licence v.3.0.
Help improve this data
Give feedback on this dataset, or email your questions and corrections to digitalland@communities.gov.uk.