Planning condition
Yorkshire Water - Water Main Protection
About this entity
| Fact links | ||
|---|---|---|
| CURIE | planning-condition:U0109819 | no fact link |
| Prefix | planning-condition | Facts about Prefix |
| Reference | U0109819 | Facts about Reference |
| Name | Yorkshire Water - Water Main Protection | Facts about Name |
| Quality | Authoritative: We have some data from the authoritative source | no fact link |
| Dataset | Planning condition | no fact link |
| Organisation | Doncaster Metropolitan Borough Council | no fact link |
| Start date | Facts about Start date | |
| End date | Facts about End date | |
| Entry date | 2025-03-20 | Facts about Entry date |
| Typology | policy | no fact link |
| Notes | Unique Condition | Facts about Notes |
| Reason | In order to allow sufficient access for maintenance and repair work at all times | Facts about Reason |
| Description | No building or other obstruction including landscape features shall be located over or within 3 (three) metres either side of the centre line of the water main i.e. a protected strip width of 6 (six) metres, that enters the site. If the required stand-off distance is to be achieved via diversion or closure of the water main, the developer shall submit evidence to the Local Planning Authority that the diversion or closure has been agreed with the relevant statutory undertaker. | Facts about Description |
Contents
{
"entry-date": "2025-03-20",
"start-date": "",
"end-date": "",
"entity": 73000525,
"name": "Yorkshire Water - Water Main Protection",
"dataset": "planning-condition",
"typology": "policy",
"reference": "U0109819",
"prefix": "planning-condition",
"organisation-entity": 109,
"geometry": "",
"point": "",
"quality": "authoritative",
"notes": "Unique Condition",
"reason": "In order to allow sufficient access for maintenance and repair work at all times",
"description": "No building or other obstruction including landscape features shall be located over or within 3 (three) metres either side of the centre line of the water main i.e. a protected strip width of 6 (six) metres, that enters the site. If the required stand-off distance is to be achieved via diversion or closure of the water main, the developer shall submit evidence to the Local Planning Authority that the diversion or closure has been agreed with the relevant statutory undertaker."
}
© Crown copyright and database right 2026
Licensed under the Open Government Licence v.3.0.
Help improve this data
Give feedback on this dataset, or email your questions and corrections to digitalland@communities.gov.uk.